For the Pharmaceutical Industry |
Use: The vessel may be used for the manufacture of toothpaste and also, under sterile conditions skin creams, shampoos, cosmetics and pharmaceutical lotions.
General Description: Cylindrical vessel with torispherical bottom and top and the top is fitted with machined mating flanges incorporating a vacuum tight seal. All materials in contact with the product are of S/ S 316 except valve seats.
Operating Pressure: Atmospheric and full Vacuum |
 |
Machine Dimensions:
- Length 3300mm
- Width 1500mm
- Height 3000mm
- Height with lid open 4200mm
- Working Volume 1200L
The vessel is mounted to a column and supported by two tubular legs Dia 80mm. Fitted to the bottom of the vessel is a 75mm outlet ball valve, together with an ingredients inlet valve. The top of the vessel is fitted to a bridge piece and mounted to a column and with the assistance of a hydraulic cylinder the top can be raised for cleaning purposes. The top of the vessel also contains 2 x 22kW high shear discs, together with a light/ sight glass and an anchor stirrer, the anchor stirrer contains a set of scraper blades and is driven by a 5.5kW geared chain drive system.
Ancillary Equipment
- The vessel is fitted with a Hydraulic Power pack required for raising and lowering the top and for inspection or cleaning purposes.
- A liquid ring Vacuum Pump, together with water makeup tank is also supplied and piped to the vessel.
- An IP55 electric panel
Price: R 385,000.00 excl. VAT ex our works |
|
| |
| Pierre Guerin 3 piston type
unit homogeniser |
| |
|
We have a reconditioned Pierre Guerin 3 piston type
unit homogeniser in stock.
Model: ALM 6
Duty: 400 ltrs
Price: R 50 000.00 |
| |
|
Sterilization Cabinet
|
|
Click image to enlarge |
The Sterilization Cabinet
was designed to sterilize vials for the Pharmaceutical Industries.
Dimensions: The internal
dimension of the oven is 2.5m (L) x 1.95 (H) and 1.25m (W) with
2 access doors, one for loading, and one for unloading of trolleys
containing items for sterilizing.
The cabinet is fitted with Hepa filter, to ensure that hygienic
air is introduced for the sterilization cycle, which may be set
as high as 200ºC by use of 75kw non shedding electrical elements.
The trolleys with trays are designed to take vials with a maximum
height of 180mm. |
| |
Control: The oven
is fitted wit a P.L.C for cycle control monitoring and logging heat-up
temperature with sterilization time and cool down cycle utilizing
fresh air via the Hepa filter.
|
|